STUDI ANALISA PENGARUH PERUBAHAN TAP CHANGER TRANSFORMATOR DAYA PADA GARDU INDUK SOLOK PT PLN(PERSERO) WILAYAH SUMBAR

Lolli, Fachmiriati and Ija, Darmana and Cahayahati, Cahayahati (2020) STUDI ANALISA PENGARUH PERUBAHAN TAP CHANGER TRANSFORMATOR DAYA PADA GARDU INDUK SOLOK PT PLN(PERSERO) WILAYAH SUMBAR. Diploma thesis, Universitas Bung Hatta.

[img] Text
38. Lolli Fachmiriati 1610017111011 Cover.pdf

Download (42kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 Abstrak.pdf

Download (28kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 BAB I.pdf

Download (56kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 BAB II.pdf
Restricted to Repository staff only

Download (926kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 BAB III.pdf
Restricted to Repository staff only

Download (191kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 BAB IV.pdf
Restricted to Repository staff only

Download (878kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 BAB V.pdf

Download (53kB)
[img] Text
38. Lolli Fachmiriati 1610017111011 Daftar Pustaka.pdf

Download (42kB)

Abstract

The State Electricity Company strives to provide electric power services according to consumer needs by providing an electric power system that is of high quality, continuity and reliability. This can be achieved if the electric power system has constant stability and voltage at predetermined values. In fact, it is difficult to get a constant voltage because high load currents will cause losses and voltage drops. The tap changer is a very important component in a transformer. Due to the voltage drop across the feeder, the voltage on the consumer side will be lower than the nominal value. To meet the needs of consumer voltage, the tap changer will experience changes due to the voltage drop that occurs in the Solok substation power transformer. In the normal position of the tap changer (6t hposition) the 20 MVA power transformer sent a voltage of 20.6 kV, the 60 MVA power transformer sent a voltage of 20.7 kV, is in the tap position 6. From the results of the analysis, it is found that a voltage drop of + 10% is found in the batu plano feeder, to get constant voltage, then the tap changer is changed to the 20 MVA power transformer by sent the voltage to 20.9 kV, the 60 MVA power transformer sent a voltage of 21 kV, is in the tap position 5, with a voltage drop efficiency value of ± 5%. Keywords: Power transformer, tap changer, voltage drop.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro
Depositing User: Ahmad Elzuhri
Date Deposited: 24 Nov 2020 08:54
Last Modified: 24 Nov 2020 08:54
URI: http://repo.bunghatta.ac.id/id/eprint/1670