ANALISA PENGARUH KORONA TERHADAP RUGI-RUGI DAYA BERDASARKAN KONFIGURASI KAWAT BERKAS PADA SUTET 275 kV DARI GI KILIRAN JAO – GI PAYAKUMBUH

Olma, Savitry and Cahayahati, Cahayahati and Yani, Ridal (2021) ANALISA PENGARUH KORONA TERHADAP RUGI-RUGI DAYA BERDASARKAN KONFIGURASI KAWAT BERKAS PADA SUTET 275 kV DARI GI KILIRAN JAO – GI PAYAKUMBUH. Diploma thesis, UNIVERSITAS BUNG HATTA.

[img] Text
32 Cover.pdf

Download (386kB)
[img] Text
32 Abstrak.pdf

Download (75kB)
[img] Text
32 BAB I.pdf

Download (170kB)
[img] Text
32 BAB II - IV.pdf
Restricted to Registered users only

Download (940kB)
[img] Text
32 BAB V.pdf

Download (89kB)
[img] Text
32 Daftar Pustaka.pdf

Download (1MB)

Abstract

Electric power transmission is the process of channeling electric power from the place of the power plant (Power Plant) to the substation distribution so that it can be distributed to the consumer electricity users through a conductor material. In the distribution of electrical power distribution losses will occur in the amount proportional to the length of the channel. The use of higher voltage levels is a solution to this problem. However, if the voltage continues to increase, corona events will occur. In the corona event there are several factors that influence namely natural factors and technical factors, so that corona losses can be minimized, this study analyzed the influence of corona on power losses based on the configuration of wire bundles on SUTT 275 kV from GI KiliranJao - GI Payakumbuh . If the corona critical voltage (Vkk) is higher than the line voltage to neutral (VLN), the corona power losses (PK) are 0 either in wet or dry conditions, but when wet conditions corona losses will appear more quickly ( Vkk> VLN). Corona power losses with 2 bundle conductors at the distance of the sub conductor beam, during wet weather conditions the distance between sub conductors is d = 1.4225 cm. And when conditions are dry equal to d = 2.4225 cm. And if you use a bundle without a bundle, large corona power losses will appear in both wet and dry conditions (VKK <VLN). Key words: SUTT 275 kV, Corona, power losses, and bundle configuration

Item Type: Thesis (Diploma)
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro
Depositing User: Heltree Ivatureza
Date Deposited: 22 Apr 2021 07:09
Last Modified: 20 May 2021 07:38
URI: http://repo.bunghatta.ac.id/id/eprint/3351

Actions (login required)

View Item View Item