PERENCANAAN KOORDINASI PROTEKSI ARUS HUBUNG SINGKAT MENGGUNAKAN HYBRID SUPERCONDUCTING FAULT CURRENT LIMITER (SFCL) PADA SISTEM TENAGA LISTRIK 6,3 KV PT. SEMEN PADANG TBK.

Perisman, Perisman and Cahayahati, Cahayahati and Indra, Nisja (2020) PERENCANAAN KOORDINASI PROTEKSI ARUS HUBUNG SINGKAT MENGGUNAKAN HYBRID SUPERCONDUCTING FAULT CURRENT LIMITER (SFCL) PADA SISTEM TENAGA LISTRIK 6,3 KV PT. SEMEN PADANG TBK. Diploma thesis, Universitas Bung Hatta.

[img] Text
37. Perisman 1610017111003 Cover.pdf

Download (264kB)
[img] Text
37. Perisman 1610017111003 Abstrak.pdf

Download (429kB)
[img] Text
37. Perisman 1610017111003 BAB I.pdf

Download (255kB)
[img] Text
37. Perisman 1610017111003 BAB II.pdf
Restricted to Repository staff only

Download (905kB)
[img] Text
37. Perisman 1610017111003 BAB III.pdf
Restricted to Repository staff only

Download (246kB)
[img] Text
37. Perisman 1610017111003 BAB IV.pdf
Restricted to Repository staff only

Download (806kB)
[img] Text
37. Perisman 1610017111003 BAB V.pdf

Download (214kB)
[img] Text
37. Perisman 1610017111003 Daftar Pustaka.pdf

Download (288kB)

Abstract

The electrical system is an important part of a company. Short circuit fault is the most common fault in the electrical system. The amount of fault current can cause a trip at a point area. PT. Semen Padang has experienced a trip because of a short circuit. The large short circuit current makes the PLN relay work first, because it is only an inverse relay only that works so if there is a large short circuit current the PLN relay will immediately trip first. One way to reduce large short circuit currents is by adding SFCL. The tarfo 7 bus has a large short circuit current rating, therefore the SFCL is installed parallel to the bus. The short circuit current on the bus transformer 7 before being given SFCL is 143,931 kA. This short circuit current makes the PLN relay work first. After the SFCL is installed, the symmetric short circuit current on the bus of transformer 7 is reduced to 21.071 kA. The addition of the impedance of 3,637.31 ohms can solve the problem that is at PT. Semen Padang and the result of the addition of SFCL also be done setting again to relay overcurrent. With the installation of Hybrid SFCL, it can reduce short circuit currents and still maintain the continuity of power supply at PT. Semen Padang . Keywords : Hybrid SFCL, Protection Coordination, Overcurrent Relay.

Item Type: Thesis (Diploma)
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro
Depositing User: Ahmad Elzuhri
Date Deposited: 24 Nov 2020 08:50
Last Modified: 24 Nov 2020 08:50
URI: http://repo.bunghatta.ac.id/id/eprint/1669